ZEL-100 Data LoMo Data Acquisition Software / Data LoMo Datalogger Software
Introduction
Data LoMo data acquisition software is used to simplify the data acquisition process. The friendly user interface shortens the learning time of the software. The user can name and unit each channel. The software itself automatically recognizes the DAQ and power meter heads of different manufacturers. As well as the TSI particle counter, other functions include querying historical records and exporting Excel data.
Features
- Real-time display and recording of multi-channel data to disk
- Display single-channel or multi-channel data graph
- Database (SQLite) Manage multi-channel data
- Export files compatible with EXCEL at the same time
- User management mode can record different user actions
- Label and data unit can be named for each point
- An external large monitor can display real-time data (optional hardware)
- External alarm function (optional hardware)
- Support Windows 7 32/64 bit or higher operating system
Real-time data graph | historical data |
Specifications
model | ZEL-100 Data LoMo |
working system | Windows 10 is downward compatible to Windows XP |
language | Traditional Chinese / Simplified Chinese / English |
Memory capacity | 512MB or more |
Hard disk capacity | 2 GB or more |
monitor | Resolution 1366 X 768 or higher |
Office features | Office XP or above must be installed |
Model No. | IO – 200 | |
Channels | 1 ~ 8 by Hardware | |
Sensor Type
Analog Input |
Thermocouple | J, K, T, E, R, S, B, N, C, L, M, Thermistor, LDIN43710, 2/3-wire RTD |
Voltage | ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V ±50 V, ±150 V | |
Current | ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA | |
Other | Temperature / Humidity / Illumination ( Lux, UV, IR ) / Flow / Liquid Level / Gas sensor
For 4~20mA or 0~10V |
|
Resolution | 16 bit | |
Accuracy | 0.1% For Normal Mode, 0.1% For Fast Mode | |
Sampling Rate | 10 Hz | |
Interface | RS-485 | |
Baud Rate | 1200 ~ 115200 bps | |
Input Power | 10 ~ 30 VDC | |
Optional | ||
Sensor | ||
Power Supply ( 12V / 24V ) | ||
USB to RS-485 Converter | ||
485 Gateway | ||
Lora Wireless transmitter receiver |
Model No. | ZC5H |
Channels | 1 |
Sensor Type
Analog Input |
AC / DC Voltage, AC / DC Current, Potentiometer, Resistance, Transmitter, PT-100, Load Cell
Thermocouple J, K, T, E, R, S, B |
Resolution | 15 bit |
Accuracy | ±0.1% FSR, ±1Digi ( DC / Potentiometer / Resistance / Transmitter / PT-100 / Load Cell )
±0.2% FSR, ±1Digi ( AC ) |
Sampling Rate | 16 Hz |
Interface | RS-485 |
Baud Rate | 4800 ~ 38400 bps |
Input Power | 24 ~ 60 VDC / 100 ~ 240 VAC |
Optional | |
Sensor | |
Power Supply ( 12V / 24V ) | |
USB to RS-485 Converter | |
485 Gateway | |